VRF / VRV central air conditioning

One outdoor system, many indoor units and individual control for every room.

Group of air conditioning outdoor units
Quick answer

VRF (Variable Refrigerant Flow), called VRV by Daikin, connects many indoor units to one outdoor system through refrigerant piping. Inverter compressors vary the refrigerant flow so each room gets only the cooling it needs. It suits offices, hotels, hospitals, villas and showrooms that need room-by-room control.

How a VRF system works

VRF system: one outdoor unit connected by refrigerant piping and branch joints to four indoor units in different rooms, with a central controller Outdoor unit inverter compressors on roof / terrace Cabinwall-mounted Conference4-way cassette Open officeducted Lobbyfloor-standing refrigerant piping with branch joints Central controller / BMS liquid line gas line

Simplified: one outdoor system serves several zones, and each indoor unit is controlled separately.

Inverter compressors in the outdoor unit vary the flow of refrigerant to each indoor unit according to that room's load. Rooms that need more cooling get more refrigerant; empty rooms get little or none. This part-load efficiency is the main reason VRF has replaced many ductable and split installations in offices and hotels.

Types of VRF system

Heat pump VRFAll connected indoor units cool, or all heat, at the same time. The most common choice for Indian offices, homes and shops.
Heat recovery VRFSome zones can cool while others heat, with heat moved between them. Useful for hotels and hospitals with mixed needs.
Water-cooled VRFThe outdoor unit rejects heat to a water loop instead of air, for tall buildings or where outdoor space is limited.

Indoor unit options

One VRF system can mix indoor unit styles to suit each room: wall-mounted units for cabins, 4-way cassettes for conference rooms, concealed ducted units for open offices and lobbies, ceiling-suspended units for halls and floor-standing units where there is no false ceiling.

VRF vs ductable vs chilled-water

VRF / VRVDuctableChilled-water
Zone controlEvery room separatelyOne unit per large zonePer AHU / FCU
Part-load efficiencyHigh (inverter)Lower, unless inverterHigh at large scale
Space neededSmall pipes, no plant roomLarge ducts above ceilingPlant room, pumps, AHU rooms
Best size rangeSmall to large commercial buildingsSingle large floorsVery large buildings and plants
Typical buildingsOffices, hotels, hospitals, villas, showroomsFactories, halls, auditoriumsHospitals, pharma, malls, campuses

VRF brands we supply

We supply and install VRF systems from six brands: Daikin (VRV), Mitsubishi Electric (City Multi), Mitsubishi Heavy Industries (KX series), LG (Multi V), Haier (MRV) and Blue Star, so the recommendation follows your building and budget.

What our VRF execution includes

  • Heat load calculation per room, with diversity, and outdoor unit sizing
  • Refrigerant piping design within the manufacturer's length and height limits
  • Copper piping brazed under nitrogen to keep pipes clean inside
  • Pressure testing, deep vacuuming and refrigerant charge calculated for actual pipe lengths
  • Drain piping, insulation, controls and central controller or BMS integration
  • Commissioning with the brand's checks, then AMC

Frequently asked questions

What is a VRF system?

VRF (Variable Refrigerant Flow) is a central air conditioning system in which one outdoor unit, or a group of outdoor units, connects to many indoor units through refrigerant piping. Inverter compressors vary the refrigerant flow so each room gets only the cooling it needs.

What is the difference between VRF and VRV?

There is no technical difference. VRV (Variable Refrigerant Volume) is Daikin's trademark name; other brands call the same technology VRF.

Is VRF better than a ductable AC?

VRF is usually better when many rooms need individual control and ceiling space is limited, as in offices, hotels and hospitals. Ductable ACs suit single large floors such as factories and halls.

Is a VRF system energy efficient?

Yes, especially at part load. Buildings rarely need full cooling in every room at once, and VRF's inverter compressors reduce output to match the actual demand.

Which VRF brands do you supply in Vadodara?

Daikin VRV, Mitsubishi Electric City Multi, Mitsubishi Heavy Industries KX, LG Multi V, Haier MRV and Blue Star VRF systems, with design, installation, commissioning and AMC.

How is a VRF system maintained?

Regular filter and coil cleaning on indoor units, outdoor unit coil cleaning, checking drains, controls and refrigerant pressures, and error-log checks through the controller. An AMC covers this on a schedule.